2023年1月31日,美國(guó)EPA發(fā)布了計(jì)算機(jī)服務(wù)器能源之星4.0版本的最終草稿版,并公布此版本將于2024年1月12日正式生效,
4.0版最終草稿相比3.0版更新如下:
更新一:
在產(chǎn)品類(lèi)型中增加了Storage Heavy Server (SHS)和Hyperconverged Server這兩個(gè)新的類(lèi)別的定義(備注:SHS定義中的存儲(chǔ)設(shè)備必須是內(nèi)部存儲(chǔ)設(shè)備。),但是目前暫未將Hyperconverged Server列入需要能源之星認(rèn)證的名單。
Storage Heavy Server (SHS): A computer server with greater storage capacity than a standard computer server. As shipped, these computer servers support 30 or more storage devices. These servers differ from Storage Products in that they run computer server operating systems and software stacks.
Hyperconverged Server: A highly integrated server which contains the additional features of large network equipment and storage products
更新二:
更新了電源模塊的能效要求。
原3.0版本要求,所有輸出功率采用相同的能效要求:
Table 1: Efficiency Requirements for PSUs
Power Supply Type | Rated Output Power | 10%Load | 20%Load | 50%Load | 100%Load |
Multi-output(Ac-Dc) | All Output Levels | N/A | 90% | 92% | 89% |
Single-output(Ac-Dc) | All Output Levels | 83% | 90% | 94% | 91% |
4.0版本把電源輸出以750W為界限劃定了不同的能效要求:
Table 1: Efficiency Requirements for PSUs4
Power Supply Type | Rated Output Power(W) | 10%Load | 20%Load | 50%Load | 100%Load |
Multi-output(Ac-Dc) | 750 watts or greater | N/A | 90% | 92% | 89% |
Single-output(Ac-Dc) | Less than 750 watts | N/A | 87% | 90% | 87% |
Single-output(Ac-Dc) | 750 watts or greater | 90% | 94% | 96% | 91% |
Power Supply Type | Rated Output Power(W) | 10%Load | 20%Load | 50%Load | 100%Load |
Multi-output(Ac-Dc) | Less than 750 watts | 83% | 90% | 94% | 91% |
更新三:
更新了并提高了計(jì)算機(jī)服務(wù)器的活動(dòng)狀態(tài)效率閾值的要求。
原3.0版本對(duì)于所有計(jì)算機(jī)服務(wù)器的活動(dòng)狀態(tài)效率閾值要求:
Table 3: Active State Efficiency Thresholds for all Computer Servers
Product Type | Minimum EffAcTIV |
One Installed Processor | |
Rack | 11.0 |
Tower | 9.4 |
Blade or Multi-Node | 9.0 |
Resilient | 4.8 |
Two lnstalled Processors | |
Rack | 13.0 |
Tower | 12.0 |
Blade or Multi-Node | 14.0 |
Resilient | 5.2 |
Greater Than Two Installed Processors | |
Rack | 16.0 |
Blade or Multi-Node | 9.6 |
Resilient | 4.2 |
4.0版本中對(duì)于非大容量服務(wù)器的活動(dòng)狀態(tài)效率閾值要求:
Table 3: Active State Efficiency Thresholds for all non-SHS Computer Servers
Product Type | Minimum EffAcTIV |
One Installed Processor | |
Rack | 26.4 |
Tower | 24.4 |
Resilient | 6.6 |
Two lnstalled Processors | |
Rack | 30.4 |
Tower | 26.5 |
Blade or Multi-Node | 29.1 |
Resilient | 6.0 |
Greater Than Two Installed Processors | |
Rack | 31.9 |
Blade or Multi-Node | 26.8 |
我們秉承科學(xué)嚴(yán)謹(jǐn)?shù)墓ぷ鲬B(tài)度,以客戶(hù)為中心,高效統(tǒng)籌安排測(cè)試計(jì)劃,竭力縮短測(cè)試時(shí)間的周期,為客戶(hù)提供快捷、公正的第三方咨詢(xún)檢測(cè)等服務(wù)。服務(wù)區(qū)域遍布廣東廣州、深圳、東莞、佛山、中山、珠海、清遠(yuǎn)、惠州、茂名、揭陽(yáng)、梅州、江門(mén)、肇慶、汕頭、潮州、河源、韶關(guān)及全國(guó)各地如您有相關(guān)產(chǎn)品需要咨詢(xún),歡迎您直接來(lái)18165787025咨詢(xún)我司工作人員,獲得詳細(xì)的費(fèi)用報(bào)價(jià)與周期方案等信息,深圳訊科期待您的光臨!
上一篇:SVHC清單新增9項(xiàng)候選物質(zhì)
下一篇:阿聯(lián)酋TDRA更新型式認(rèn)證標(biāo)簽要求
- 歐盟發(fā)布新電池法規(guī)中便攜式電池和輕型運(yùn)輸工具(LMT)電池可拆卸性和可更換性指南
- 塑料聚丙烯樹(shù)脂魚(yú)眼測(cè)試方法介紹
- 剖析不同產(chǎn)品質(zhì)檢報(bào)告辦理差異
- 電視機(jī)可靠性和面板壽命測(cè)試
- 高低溫試驗(yàn)基礎(chǔ)及檢測(cè)標(biāo)準(zhǔn)
- 大型機(jī)柜可以做IP52防護(hù)等級(jí)測(cè)試嗎
- 蔬菜質(zhì)檢報(bào)告可能包含的主要內(nèi)容
- 電子電氣行業(yè)中的氣體腐蝕測(cè)試應(yīng)用
- 運(yùn)輸鑒定報(bào)告的常見(jiàn)問(wèn)題解答及應(yīng)對(duì)策略
- MSDS報(bào)告需要多長(zhǎng)時(shí)間才能拿到